Allied Telesis AR400 Series 구성 방법 - 페이지 4

{카테고리_이름} Allied Telesis AR400 Series에 대한 구성 방법을 온라인으로 검색하거나 PDF를 다운로드하세요. Allied Telesis AR400 Series 6 페이지. How to set up pppoe between a linux client and access concentrator
Allied Telesis AR400 Series에 대해서도 마찬가지입니다: 문제 해결 매뉴얼 (8 페이지), 문제 해결 (5 페이지), 빠른 설치 매뉴얼 (8 페이지), 빠른 설치 매뉴얼 (12 페이지), 안전 정보 매뉴얼 (18 페이지), 방법 (8 페이지)

Allied Telesis AR400 Series 구성 방법
An example scenario for RIP over L2TP
Routing Considerations
A routing issue to consider in this set up is the fact that RIP is relatively slow to react to
route changes as it only updates, by default, every 30 seconds.
To improve the responsiveness of RIP you can alter the default timers for updating, flushing
and so on. You do need to keep in mind that if you lose some packets (quite possible across
a lossy Internet connection) some of your routes may flap too much. So the RIP timers need
to be adjusted to provide an optimal compromise between responsiveness and robustness.
In this particular example, the various RIP timers are set at half default value.
set ip riptimer update=15 invalid=90 holddown=60 flush=150
Consideration would need to be given to each specific set up to get an optimal balance when
adjusting these timers.
Page 4 | AlliedWare™ OS How To Note: Dynamic Routing over L2TP