Dell D560F 소유자 매뉴얼 - 페이지 14

{카테고리_이름} Dell D560F에 대한 소유자 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Dell D560F 33 페이지. Emc vxrail appliances on poweredge servers

Dell D560F 소유자 매뉴얼

Drive indicator codes

The LEDs on the drive carrier indicate the state of each drive. Each drive carrier in your system has two LEDs: an activity LED
(green) and a status LED (bicolor, green/amber). The activity LED flashes whenever the drive is accessed.
Figure 7. Drive indicators
1. Drive activity LED indicator
2. Drive status LED indicator
3. Drive capacity label
NOTE:
If the drive is in the Advanced Host Controller Interface (AHCI) mode, the status LED indicator does not turn on.
Table 13. Drive indicator codes
Drive status indicator code
Blinks green twice per second
Off
Blinks green, amber, and then turns off
Blinks amber four times per second
Blinks green slowly
Solid green
Blinks green for three seconds, amber for three seconds,
and then powers off after six seconds

Back view of the system

The back view of the system displays the features available on the back of the system.
14
Dell EMC VxRail D Series overview
Condition
Indicates that the drive is being identified or preparing for removal.
Indicates that the drive ready for removal.
NOTE:
The drive status indicator remains off until all drives
are initialized after the appliance is turned on. Drives are not
ready for removal during this time.
Indicates that there is an expected drive failure.
Indicates that the drive failed.
Indicates that the drive is rebuilding.
Indicates that the drive is online.
Indicates that the drive rebuilt has stopped.