Dell PowerEdge FD332 소유자 매뉴얼 - 페이지 12

{카테고리_이름} Dell PowerEdge FD332에 대한 소유자 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Dell PowerEdge FD332 46 페이지.
Dell PowerEdge FD332에 대해서도 마찬가지입니다: 시작하기 (2 페이지)

Dell PowerEdge FD332 소유자 매뉴얼
The storage controller(s) inside a storage sled map to compute sled(s) in the enclosure. PowerEdge FX2s supports multiple storage sled to
compute sled mapping configurations.
NOTE:
Storage sled to compute sled mapping is pre-configured.
NOTE:
The PowerEdge FM120x4 compute sled does not support the storage sled. You cannot map a storage sled to the
PowerEdge FM120x4 half-width compute sled.
For information on configuring the storage mode in the storage sleds, see the PowerEdge FX2/FX2s CMC User's Guide at dell.com/
esmmanuals.
Topics:

Single PERC/HBA Controller and joined mode mapping configurations

Split mode mapping configurations
Single PERC/HBA Controller and joined mode
mapping configurations
CAUTION:
Changing the storage sled mapping configuration from Split Single Host mode to Joined mode can change some hard
drives/SSDs to non-RAID mode.
The single PERC/HBA Controller and joined mode configurations apply to the following:
The storage sled supports a storage controller module with a single controller, and all hard drives/SSDs map to the single controller.
The storage sled supports a storage controller module with dual controllers, but only the primary controller is enabled by setting the
Storage Mode to Joined in the Chassis Management Controller (CMC) interface. All hard drives/SSDs in the storage sled map to the
primary controller in the joined mode.
The following enclosure configurations support single PERC/HBA controller and joined mode mapping.
Four-bay chassis—controllers inside two storage sleds map to two half-width compute sleds
Four-bay chassis (one compute sled)—controllers inside three storage sleds map to one half-width compute sled
Six-bay chassis—controllers inside two storage sleds map to two quarter-width compute sleds
Three-bay chassis—controllers inside two storage sleds map to one full-width compute sled
NOTE:
PowerEdge FX2s supports multiple single PERC/HBA controller and joined mode mapping configurations. You must
select the desired configuration based on your intended usage.
Figure 5. Single PERC/HBA joined mode mapping configuration—four-bay chassis
12

Storage sled mapping configurations

Storage sled mapping configurations
3