Dell PowerEdge FD332 소유자 매뉴얼 - 페이지 13

{카테고리_이름} Dell PowerEdge FD332에 대한 소유자 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Dell PowerEdge FD332 46 페이지.
Dell PowerEdge FD332에 대해서도 마찬가지입니다: 시작하기 (2 페이지)

Dell PowerEdge FD332 소유자 매뉴얼
Figure 6. Single PERC/HBA joined mode mapping configuration—four-bay chassis (one compute sled)
Figure 7. Single PERC/HBA joined mode mapping configuration—six-bay chassis
Figure 8. Single PERC/HBA joined mode mapping configuration—three-bay chassis

Split mode mapping configurations

CAUTION:
Changing the storage sled mapping configuration from Joined mode to Split mode can result in loss of configuration
and/or loss of access to hard drives/SSDs.
NOTE:
When changing the mapping configuration from Joined mode to Split mode, the secondary controller is powered on. It is
recommended that you run the latest PERC/HBA firmware Dell Update Package (DUP) to ensure that both controllers are
running the latest firmware.
The split mode mapping configurations apply to the following:
The storage sled supports a storage controller module with dual PERC/HBA controllers.
Both controllers are enabled by setting the Storage Mode to split mode in the CMC interface.
In the split mode, eight hard drives/SSDs are mapped to each controller. Hard drives/SSDs in slots 0 to 7 map to controller 1 or primary
controller, and hard drives/SSDs in slots 8 to 15 map to controller 2. For more information, see
There are two split mode options available in the CMC interface:
Split Single Host mode
Split Dual Host mode
Drive to storage controller
Storage sled mapping configurations
mapping.
13