{카테고리_이름} Christ CLM1000 Standard에 대한 사용 설명서을 온라인으로 검색하거나 PDF를 다운로드하세요. Christ CLM1000 Standard 12 페이지. Wattmeter

4.2

Display and operation

Display
Control elements
4.3

Measuring principle and accuracy

Measuring principle
Measuring rate
Sampling rate
Open-circuit
recognition
EEPROM-Memory
Measuring error
4.4

Voltage supply

Connection
Supply voltage
Power consumption
4.5

Enviroment and dimensions

Dimensions
Weight
Connection cable
Working temperature
Degree of protection
Protection class
Measuring category
E461755
128*64 Display with varying background lighting
3 membrane buttons
Voltage is measured directly at the load and current is
measured by a precision shunt.
approx. 1 second
approx. 2000 Hz
If I < 0,002 Ampere current and power values are set to zero.
It P < 0,2 Watt power values and current are set to zero.
In this case the power factor is set to 1,00.
The type of resistance is set to ohm-resistance.
All readings are saved even after unplugging
± 0,3 % ± 3 digit from reading at power factor > 0,3
Socket at the adapter, permanent load max. 16 A
100 - 264 V
, 47 - 63 Hz
AC
< 4 VA
ABS plastic casing approx. 200*95*35 [mm] (L*W*H)
approx. 490 g
approx. 1,2 m
0° C - 50° C, dew not permissible
IP 50 according to DIN EN 60529 (with USB-interface IP40)
with seal kit even higher values are permissible
Protection class II (protective insulation) according to DIN EN
61140
CAT II according to DIN EN 61010-1
10