4.2

Display and operation

Display
Control elements
4.3

Measuring principle and accuracy

Measuring principle
Measuring rate
Sampling rate
Open-circuit
recognition
EEPROM-Memory
Measuring error
4.4

Voltage supply

Connection
Supply voltage
Power consumption
4.5

Enviroment and dimensions

Dimensions
Weight
Connection cable
Working temperature
Degree of protection
Protection class
Measuring category
E461755
128*64 Display with varying background lighting
3 membrane buttons
Voltage is measured directly at the load and current is
measured by a precision shunt.
approx. 1 second
approx. 2000 Hz
If I < 0,002 Ampere current and power values are set to zero.
It P < 0,2 Watt power values and current are set to zero.
In this case the power factor is set to 1,00.
The type of resistance is set to ohm-resistance.
All readings are saved even after unplugging
± 0,3 % ± 3 digit from reading at power factor > 0,3
Socket at the adapter, permanent load max. 16 A
100 - 264 V
, 47 - 63 Hz
AC
< 4 VA
ABS plastic casing approx. 200*95*35 [mm] (L*W*H)
approx. 490 g
approx. 1,2 m
0° C - 50° C, dew not permissible
IP 50 according to DIN EN 60529 (with USB-interface IP40)
with seal kit even higher values are permissible
Protection class II (protective insulation) according to DIN EN
61140
CAT II according to DIN EN 61010-1