Dell PowerVault NX1950 구성 매뉴얼 - 페이지 10

{카테고리_이름} Dell PowerVault NX1950에 대한 구성 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Dell PowerVault NX1950 11 페이지. For vmware esx server software
Dell PowerVault NX1950에 대해서도 마찬가지입니다: 배포 매뉴얼 (34 페이지), 중요 정보 매뉴얼 (26 페이지), 시작하기 (49 페이지), 설치 및 문제 해결 매뉴얼 (48 페이지), 배포 매뉴얼 (38 페이지), 업그레이드 매뉴얼 (18 페이지), 참조 매뉴얼 (4 페이지), 설정 (2 페이지), 사용 (2 페이지)

Dell PowerVault NX1950 구성 매뉴얼
7. Configure iSCSI storage on ESX Server 
Connect to the ESX Server/VirtualCenter using VI Client and follow the steps below.
1. Go to the configuration tab and select Storage Adapters. Select the iSCSI Software
Adapter and click Rescan. The newly created iSCSI target and LUN should be visible
from the ESX server. The status of the virtual disk as shown on NX1950 Microsoft iSCSI
target software should now show as "In Use."
2. Go to the configuration tab and select Storage. Click on Add Storage, select Disk/Lun
and click Next. Select the newly added storage and click Next.
3. Select the newly created iSCSI LUN and click Next.
4. Review the disk layout and click Next.
5. Provide a name for the VMFS datastore and click Next.
6. Select the appropriate block size and capacity for the VMFS datastore and click Next.
7. Review the disk layout and click Finish to create the VMFS datastore. The new datastore
is now ready to be used for storing virtual machine images.
8. References 
1. Dell PowerVault NX1950 support documents:
http://support.dell.com/support/edocs/software/PVNX1950/
2. Drivers download page for NX1950:
http://support.dell.com/support/downloads/driverslist.aspx?os=WX64&osl=EN&catid=-
1&impid=-1&servicetag=&SystemID=PWV_NX_1950&hidos=WNET&hidlang=en
3. VMware Virtual Infrastructure 3 Documentation:
http://www.vmware.com/support/pubs/vi_pubs.html
4. Dell|VMware alliance home page:
5. Microsoft Widows Unified Storage Data Storage Server:
http://www.microsoft.com/windowsserversystem/storage/wudss.mspx
Dell Inc.
Figure 10: iSCSI target and LUNs as visible through VI client
www.dell.com/vmware
10