Dell PowerVault TL2000 시작하기 - 페이지 36

{카테고리_이름} Dell PowerVault TL2000에 대한 시작하기을 온라인으로 검색하거나 PDF를 다운로드하세요. Dell PowerVault TL2000 38 페이지. Tape library
Dell PowerVault TL2000에 대해서도 마찬가지입니다: 릴리스 정보 (3 페이지), 자주 묻는 질문 (26 페이지), 빠른 시작 매뉴얼 (7 페이지), 소프트웨어 설명서 (16 페이지), 구성 매뉴얼 (22 페이지), 중요 정보 매뉴얼 (10 페이지), 사용자 설명서 부록 (2 페이지), 시작하기 매뉴얼 (3 페이지), 첨부 파일 지침 (17 페이지), 브로셔 (4 페이지), 사용자 설명서 (20 페이지)

Dell PowerVault TL2000 시작하기
1. Unlock the cartridge magazines.
2. Remove all magazines from the library.
3. Insert cartridges in the left magazine(s). Do not store cartridges in the I/O
4. Insert cartridges in the right magazine(s).
5. Put all magazines back into the library. The library will automatically start up

Inserting the Cleaning Cartridge

See the Note below for 4U libraries with a Dedicated Cleaning Slot (DCS).
The following criteria must be followed for Auto Clean to function:
1. The Auto Clean function must be configured "On" or "Enabled".
2. A storage slot must be reserved (Res or RSVD).
3. A cleaning cartridge (CLNUxxL1) must be placed or moved to a reserved slot.
4. To install a cleaning cartridge in the 2U library:
5. To add a cleaning cartridge to a 4U Library:
1-26
Getting Started with the Dell PowerVault TL2000 and TL4000 Tape Libraries
v Using the Operator Control Panel: Control → Magazines
v Using the Web User Interface: Manage Library → Release Magazine
Station or in the dedicated cleaning cartridge slot. Refer to the Dell PowerVault
TL2000 Tape Library and TL4000 Tape Library User's Guide for more
information.
and perform an inventory check.
v OCP: Configure->Library Settings->Enabled
v Web Interface: Configure Library->General->Auto Clean->checkmark
Note: Earlier versions of the 4U library contained a Dedicated Cleaning Slot
(DCS). This DCS can be retained and is supported by future library
firmware updates. However, library firmware later than 1.95 will allow
removal of the DCS, thus enabling this slot to be used as a storage
slot. Once the DCS is removed, the Auto Clean cleaning cartridge slot
must be configured as described below. To remove the DCS, perform
the following procedure using the Operator Control Panel (OCP):
OCP->Configure->Library Settings->General->Remove
DCS->No/Yes->Save.
v Reserving a slot is accomplished by reducing the Active Slot count in any
particular logical library. A reserved slot (or slots) is always the last slot in
the last magazine of any particular logical library. A cleaning cartridge that is
in a reserved slot is available to any logical library drive even if the reserved
slot is not in that particular logical library. If the library contains multiple
logical libraries, typically, the last logical library is chosen to be the reserved
slot containing the cleaning cartridge. As with a library with a single logical
library, this slot is the last physical slot in the library (top right magazine,
uppermost rear slot).
v A cleaning cartridge must be replaced after 50 uses. Click on the remote web
interface, Monitor Library->Inventory (-) on the magazine containing the
cleaning cartridge to determine the cleaning cartridge usage count.
a. Unlock the cartridge magazines.
v Operator Control Panel: Control → Magazines
v Web User Interface: Manage Library → Release Magazine Right
b. Add the cleaning cartridge to the right magazine in the uppermost left slot.
a. Unlock the cartridge magazines.