Dell Storage Center SC220 서비스 매뉴얼 - 페이지 15
{카테고리_이름} Dell Storage Center SC220에 대한 서비스 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Dell Storage Center SC220 36 페이지. Storage enclosures
Dell Storage Center SC220에 대해서도 마찬가지입니다: 시작하기 (14 페이지), 소유자 매뉴얼 (27 페이지)
Figure 8. Power Supplies/Cooling Fan Module Status and Rear View of the Enclosure
Replacing a Power Supply/Cooling Fan Module
Use this procedure to replace failed power supply/cooling fan modules.
1 Perform a Phone Home and contact Dell Technical Support Services as described on
page
shutting down the enclosure.
2 Turn off the power supply/cooling fan module.
3 Remove the hook-and-loop strap that secures the power cable and then disconnect the
power cable from the power supply/cooling fan module.
4 Press the release tab and slide the power supply/cooling fan module out of the chassis
using the power supply/cooling fan module handle.
Dell Compellent
8. Power supply/cooling fan modules can be replaced one at a time without
Caution: The power supply/cooling fan modules are heavy. To avoid injury, use
both hands while removing the module.
Replacing Power Supply/Cooling Fan Modules
11