CAUTION:
Remove the power cable from the PSU before removing the PSU. Also, do not connect the power
cable before you insert the PSU in the chassis.
NOTE:
To comply with the GR-1089 Lightning Criteria for Equipment Interfacing with AC Power Ports, use an external
surge protection device (SPD) at the AC input of the router.

AC or DC power supply installation

NOTE:
The PSU slides into the slot smoothly. Do not force a PSU into a slot as this action may damage the PSU or the
S6100–ON chassis.
NOTE:
Ensure that you correctly install the PSU. When you install the PSU correctly, the power connector is on the right
side of the PSU.
1. Remove the PSU slot cover from the S6100-ON using a small #1 Phillips screwdriver.
2. Remove the PSU from the electro-static bag.
3. Use the grab handle and the orange tab to insert the PSU into the switch PSU slot.
Insert the PSU exposed PCB edge connector first. The PSU slot is keyed so that the PSU can only be fully inserted in one
orientation.
Figure 25. Power supply installation
a. Power supply unit
b. Release tab
When you install the PSU correctly, it snaps into place and is flushed with the back of the switch.
4. Plug in the appropriate AC three prongs power cord from the switch PSU to the external power source.
5. Repeat steps 1 through 4 above using the second PSU slot on the S6100-ON system.
NOTE:
The S6100-ON powers up when the cables are connected between the power supply and the power source.
30
Power supplies