Dell Networking S6000 System 시작하기 매뉴얼 - 페이지 11

{카테고리_이름} Dell Networking S6000 System에 대한 시작하기 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Dell Networking S6000 System 37 페이지. Dell networking s6000 high-performance 10/40 gbe top-of-rack switch
Dell Networking S6000 System에 대해서도 마찬가지입니다: 테스트 보고서 (19 페이지)

Dell Networking S6000 System 시작하기 매뉴얼

Utility Panel

The Utility panel side contains the fan and power modules.
S6000 power supplies and fan modules.
Figure 3-2. S6000 Power Supplies and Fan Modules
1 - PSU 0
2 - Fan Modules 0-2
3 - PSU 1

Power Supplies

The S6000 supports two hot-swappable PSUs. The S6000 supports AC and DC
power supplies with two air-flow directions (I/O to PSU and PSU to I/O). Two
PSUs are required for full redundancy, but the system can operate with a single
PSU.
NOTE: If you use a single PSU, install a blank plate in the other PSU slot. Dell
Networking recommends using power supply 1 (PSU1) as the blank plate slot.
The PSUs are field replaceable. When running with full redundancy (two power
supplies installed and running), you can remove and replace one PSU while the
other PSU is running without disrupting traffic.
The S6000 does not support mixing PSU types. You cannot replace an AC PSU
with a DC PSU and you cannot replace an AC-R PSU with a DC-R PSU.
Figure 3-2
shows the
Hardware Overview
7