The switch is installed in an environment as free as possible from dust and foreign conductive material
(such as metal flakes from construction activities). Cooling mechanisms, such as fans and blowers in
the switch, can draw dust and other particles causing contaminant buildup inside the chassis, which
can result in system malfunction.
The Z9500 switch does not support installation in a 1070 mm cabinet with a door.
To install the switch, Dell Networking recommends that you complete the installation procedures in
the order presented below.
NOTE: Always handle the system and its components with care. Avoid dropping the chassis or its
field replaceable units.
NOTE: For proper ventilation, position the chassis in an equipment rack (or cabinet) with a
minimum of 5 inches (12.7 cm) of clearance around exhaust vents. The acceptable ambient
temperature ranges are listed in the Environmental Parameters section.
CAUTION: Always wear an ESD-preventive wrist or heel ground strap when handling the
switch and its components. Ground yourself by using an antistatic wrist strap or other device
and connect it to the ESD grounding jack on the chassis. As with all electrical devices of this
type, take all necessary safety precautions to prevent injury when installing this system.
Assemble 4–Post Rack Frame
The chassis can be installed only in a 4–post rack frame.
Follow the instructions in your rack frame kit to install the 4–post rack frame.
6
Getting Started Guide