Dell PowerConnect M8428-k 사용자 설명서 - 페이지 23
{카테고리_이름} Dell PowerConnect M8428-k에 대한 사용자 설명서을 온라인으로 검색하거나 PDF를 다운로드하세요. Dell PowerConnect M8428-k 23 페이지. Dell poweredge m710 and m710hd - system memory update
Dell PowerConnect M8428-k에 대해서도 마찬가지입니다: 업데이트 매뉴얼 (32 페이지), 릴리스 정보 (27 페이지), 매뉴얼 (25 페이지), 업데이트 매뉴얼 (1 페이지)
Rev 1.0
Table 9 - SFP+ Pinout
Pin
Symbol Name
15
VccR
16
VccT
17
VeeT
18
TD+
19
TD-
20
VeeT
a. Circuit ground is internally isolated from chassis ground.
b. T
FAULT
Ohms resistor on the host board if intended for use. Pull up voltage should be between 2.0V
to Vcc + 0.3V. A high output indicates a transmitter fault caused by either the TX bias cur-
rent or the TX output power exceeding the preset alarm thresholds. A low output indicates
normal operation. In the low state, the output is pulled to <0.8V.
c. Laser output disabled on TDIS >2.0V or open, enabled on TDIS <0.8V
d. Should be pulled up with 4.7kΩ – 10kΩ on host board to a voltage between 2.0V and 3.6V.
MOD_ABS pulls line low to indicate module is plugged in.
e. LOS is open collector output. Should be pulled up with 4.7kΩ – 10kΩ on host board to a
voltage between 2.0V and 3.6V. Logic 0 indicates normal operation; logic 1 indicates loss of
signal.
24
Receiver Power Supply
Transmitter Power Supply
Transmitter Ground (Common with Receiver Ground)
Transmitter Non-Inverted DATA in. AC Coupled.
Transmitter Inverted DATA in. AC Coupled.
Transmitter Ground (Common with Receiver Ground)
is an open collector/drain output, which should be pulled up with a 4.7k – 10k
Description
a
a