Dell PowerEdge M420에 대해서도 마찬가지입니다: 정보 업데이트 (38 페이지), 릴리스 정보 (27 페이지), 매뉴얼 (25 페이지), 사용자 설명서 (23 페이지), 중요 정보 매뉴얼 (35 페이지), 업데이트 매뉴얼 (32 페이지), 업데이트 매뉴얼 (28 페이지), 사용자 설명서 (26 페이지), 사용자 설명서 (22 페이지), 시작하기 매뉴얼 (12 페이지), 매뉴얼 (38 페이지), 기술 매뉴얼 (46 페이지), 포트폴리오 매뉴얼 (27 페이지), 시작하기 매뉴얼 (14 페이지), 시작하기 매뉴얼 (12 페이지)

Dell PowerEdge M420 기술 매뉴얼
Thermal control also detects and responds to hardware configuration. Thermal management
adjusts cooling according to what the system really needs, and draws lower fan power draw and
generates lower acoustical noise levels than those without such controls.
Environmental specifications: The optimized thermal management makes the PowerEdge
M420 reliable under a wide range of operating environments as shown in Table 23. When
operating above 30°C ambient, performance impacts may be seen. For more information see
Dell PowerEdge M420 Systems Owner's Manual
the
Acoustical performance
The acoustical performance of the PowerEdge M420 is reflected in Table 15.
Four sleeves, each containing four typically
host chassis; all blades had the same configuration and same airflow impedance. Remaining blade
slots were filled with blanks of same impedance as blades. Acoustical measurements were made in
23 ± 2 °C ambient.
The M420 is built for high density and high performance. The great power density of the M420
means that small increases in utilization require large increases in fan speed, hence large increases
in loudness. This means that loudness with an M420 increases significantly with utilization; in fact,
more so than other Dell blade products.
Configuration
CPUs
(23 ± 2°C ambient)
1
Typical
2 x 95W
1
Typical configuration means 2x 95W CPUs, x 2GB DIMMs, 1x Mezzanine card and 1x uSATA SSD.
2
L
-UL is the upper limit sound power levels (L
WA
accordance to ISO 7779 (2010).
3
L
is the average A-weighted sound pressure level from the four bystander positions calculated per section 4.3 of
pA
ISO 9296 (1988) and measured in accordance with ISO 7779 (2010). The system is placed in a half rack enclosure (base
of system is 25 cm above reflective floor).
4
Operating is a mode per ISO 7779 (2010) definition 3.1.6. Blade stressing applications vary widely thus also do respective
operating acoustical values; the values are given above as a likely range, for example, "likely greater than or equal to,"
(≥). SPECPower™ at 50 percent utilization is the benchmark used for the lower bound here.
5
Idle: Reference ISO 7779 (2010) definition 3.1.7; system is running in its operating system but no other specific activity;
PowerEdge M420 Technical Guide
30
1
configured M420 blades, were installed in the M1000e
Table 15.
M420 acoustical performance
Drives
DIMMs
1 x uSATA
SSD
) calculated per section 4.4.1 of ISO 9296 (1988) and measured in
WA
on Dell.com/Support/Manuals.
Operating
PCI cards
Operating
1 mezzanine
6
card
2
L
-UL
WA
mode
(bels)
4
8.9
5
Idle
7.9
3
L
pA
(dBA)
71
63