AVYCON AVR-HN504P4 빠른 시작 매뉴얼
{카테고리_이름} AVYCON AVR-HN504P4에 대한 빠른 시작 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. AVYCON AVR-HN504P4 2 페이지.
Network Video Recorder
Quick Start Guide
Note: Please read this instruction carefully for correct use of the product and preserve it for reference purposes.
All the examples and pictures used here are for reference only. There may be several technically incorrect places
or printing errors in this manual. The updates will be added into the new version of this manual. The contents of
this manual are subject to change without notice.This device should be operated only from the type of power
source indicatedon the marking label. The voltage of the power must be verified before using the same.
1. Packing Check
Please check the device and the accessories after getting the device.
If there are any damages, shortages or defects, please contact your
dealer immediately.
2. HDD Installation
This series of the product supports 8 SATA hard drives.
The pictures of the installation are only for reference, please take the
real object as standard. Please make sure that the device is powered off
before installation
1. Remove the cover and loosen the screws to take out two mounting bars.
2. Get ready the HDDs installed and fix the HDDs on the mournting bar.
(For installing the HDDs well, please fix the round screw holes first)
3. Install the mounting bar with HDDs back to the device.
4. Connect the power and data cables.
5. Install the upper four HDDs as the method mentioned above and
install back cover
3. Rear Panel Installation
ALARM OUT
RS 485
P/Z
Z
Y
VGA
B
A
LAN 1
LAN 2
HDMI 2
USB3.0
USB
HDMI 1
K/B
Internet
12
The interfaces of the rear panel are for reference only.
4. Startup & Shutdown
• Startup
1. Connect the monitor and the power.
2. The device will boot and the power indicator will display blue.
3. A wizard window will pop up.
• Shutdown
Go to "Main Menu" and then select "Shutdown" icon. This will bring
up a shutdown window. The device will shut down by clicking "OK"
button. Then disconnect the power.
4. Login
For our HN500 series NVRs, the default username is admin and the
default password is 123456. When starting HN500 series NVR for
the first time, you will see a prompt to begin a startup wizard. You can
skip this wizard if you would like, but it will help you configure basic
settings for your NVR. The wizard may allow you to also change the
default password for better security. If you decide to skip the wizard,
to access the live view and start using your NVR click on the Start
button in the bottom left of the menu bar on the bottom of the
screen and then click on Login and enter in the default password.
Login
Username
admin
Password
Enter Password
Display Password
Log In Automatically
Edit Security Question
Login
5.
Network Configuration
After you finish adding IP cameras, you can see the live images through
the monitor of the NVR. The following will mainly introduce how to add
the IP cameras via LAN/WAN. This NVR has two network ports, you can
select the network work pattern as required. Network fault tolerance
and multiple address setting are optional.
Network Fault Tolerance: Bound two network ports to one IP address.
This pattern can increase the network bandwidth and form a network
redundant array to share the load. When one port goes wrong, the
otehr port will take over the entire load immediately and seamlessly.
Multiple Address Setting: You shall set the IP address, subnet mask,
e-SATA 1
e-SATA 2
gateway and DNS of each ethernet port respectively.
ALARM IN
AUDIO
OUT
7
5
3
1
The pictures are only for referenc, please refer to User anua for details
• LAN
1. Set the network of the NVR. Go to Start → Settings →
AUDIO
8
6
2
4
IN
Network → TCP/IP. Input IP address, subnet mask, gateway,
etc. If using DHCP, please enable DHCP in both the NVR and
the router.
2. Go to Start → Settings → Network → Port. Input HTTP port
(the default value is 80), server port (the default port is 6036).
3. Click "Apply" to save the settings.
IP Address Settings
Work Pattern
Obtain an IPv4 address automatically
Address
Subnet Mask
Gateway
Primary Card
Ethernet Port 1 ( Online )
MCA Address
MTU
Obtain DNS automatically
Preferred DNS
4. Go to Start → Settings → Camera → Add Camera. The NVR
will automatically refresh the cameras searched. The IPC which
supports the Onvif protocol may be added manually. If the IPC
searched is not in the same local network as the NVR, you
should select the device and click
Quickly Add
No.
1
2
3
Selected: 1/3
Remain Bandwidth: 108 / 120 Mb
Cancel
Network Fault Tolerance
(Modifying work pattern need to reboot )Gateway
Obtain an IPv6 address automatically
192 . 168 .
1 .
2
Address
0
.
0
.
0 .
0
Mask Length
0
192 . 168 .
1 .
1
Gateway
Ethernet Port 1
Ethernet Port 2 ( Online )
10 . 151 . 151 .
1
MAC Address
1500
.
.
.
to modify the IP address.
Add Camera
Manually Add
Add Recorder
Port
Edit
Subnet Mask
Protocol
Model
Address
192.168.1.20
80
255.255.255.0
XXX
XXX
192.168.1.38
80
255.255.255.0
XXX
XXX
192.168.2.45
80
255 255 255 0
.
.
.
XXX
XXX
4.0.0.1.beta1
Default Password
Add
Edit Camera
CE :98 :23 :75 :35 :22
Mac Address
Address
192 .168 . 1 . 45
Sync to IPC
Subnet Mask
255 . 255 . 255 . 0
Gateway
192 .168 . 1 . 1
Username
admin
Password
OK
Cancel
Version
3.4.2
3.4.2