Award PPS863BS SI 사용 설명서 - 페이지 8

{카테고리_이름} Award PPS863BS SI에 대한 사용 설명서을 온라인으로 검색하거나 PDF를 다운로드하세요. Award PPS863BS SI 12 페이지.

DUCTED VERSION AIR EXHAUST SYSTEM When
installing the ducted version, connect the hood to the
chimney using either a flexible or rigid pipe ø 150 or
120 mm, the choice of which is left to the installer
(ø 150 mm is recommended for optimum performance).
• To install a ø 120 mm air exhaust connection, insert
the reducer flange 9 on the hood body outlet.
• Fix the pipe in position using sufficient pipe clamps
(not supplied).
• Remove possible charcoal filters.
RECIRCULATION VERSION AIR OUTLET
• Cut a hole ø 125 mm in any shelf that may be posi-
tioned over the hood.
• Insert the reducer flange 9 on the hood body outlet.
• Connect the flange to the outlet on the shelf over the
hood by using a flexible or rigid pipe ø120 mm.
• Fix the pipe in position using sufficient pipe clamps
(not supplied).
• Fix the air outlet grid 8 on the recirculation air outlet
by using the 2 screws 12e (2,9 x 9,5) provided.
• Ensure that the activated charcoal filters have been
inserted.
• Connect the hood to the mains through a two-pole switch having a contact gap of at least 3
mm..
EN
Connections
ELECTRICAL CONNECTION
ø 150
9
12e
ø 125
ø 120
8
9
8
8