DUCTED VERSION AIR EXHAUST SYSTEM When
installing the ducted version, connect the hood to the
chimney using either a flexible or rigid pipe ø 150 or
120 mm, the choice of which is left to the installer
(ø 150 mm is recommended for optimum performance).
• To install a ø 120 mm air exhaust connection, insert
the reducer flange 9 on the hood body outlet.
• Fix the pipe in position using sufficient pipe clamps
(not supplied).
• Remove possible charcoal filters.
RECIRCULATION VERSION AIR OUTLET
• Cut a hole ø 125 mm in any shelf that may be posi-
tioned over the hood.
• Insert the reducer flange 9 on the hood body outlet.
• Connect the flange to the outlet on the shelf over the
hood by using a flexible or rigid pipe ø120 mm.
• Fix the pipe in position using sufficient pipe clamps
(not supplied).
• Fix the air outlet grid 8 on the recirculation air outlet
by using the 2 screws 12e (2,9 x 9,5) provided.
• Ensure that the activated charcoal filters have been
inserted.
• Connect the hood to the mains through a two-pole switch having a contact gap of at least 3
mm..
EN
Connections
ELECTRICAL CONNECTION
ø 150
9
12e
ø 125
ø 120
8
9
8
8