Miele PW 6241 사용 설명서 - 페이지 38

{카테고리_이름} Miele PW 6241에 대한 사용 설명서을 온라인으로 검색하거나 PDF를 다운로드하세요. Miele PW 6241 46 페이지.
Miele PW 6241에 대해서도 마찬가지입니다: 작동 및 설치 지침 (44 페이지), 작동 및 설치 지침 (44 페이지), 프로그래밍 지침 매뉴얼 (48 페이지)

Miele PW 6241 사용 설명서
Notes for the installer

Plumbing

Connection must be made to the water
supply via a stopcock which conforms to
local and national regulations. This work
must be carried out by an authorised person
in accordance with local and national
regulations.

Water inlet / drainage

See the enclosed installation diagram.
To ensure trouble free operation of the
machine the flow pressure must be at least
100 kPa (1 bar) and not exceed 1000 kPa
(10 bar).
The inlet pressure tested hoses supplied
with the machine must be used for
connection to the water supply.
38
Cold water
Hot water
Before screwing the inlet hoses onto the
machine make sure you fit the filters and
seals in them which are supplied in the
accessories pack with the machine.
If replacing an inlet hose only use a hose
tested to at least 7000 kPa (70 bar)
pressure, and for a water temperature of at
least 90 °C. This also applies to all fittings.
Genuine Miele original parts fulfil these
requirements.
Water taken into the machine must not
exceed a temperature of 70°C.
Hard water
M.-Nr. 06 572 495