Miele DA 220-3 작동 및 설치 지침 - 페이지 30

{카테고리_이름} Miele DA 220-3에 대한 작동 및 설치 지침을 온라인으로 검색하거나 PDF를 다운로드하세요. Miele DA 220-3 32 페이지. Ventilation system
Miele DA 220-3에 대해서도 마찬가지입니다: 작동 및 설치 지침 (36 페이지), 작동 및 설치 지침 (32 페이지), 작동 및 설치 지침 (36 페이지)

Air extraction
If the exhaust is ducted into an inactive
flue, the air must be expelled parallel to
the flow direction of the flue.
Never connect an exhaust hood to
an active chimney, dryer vent, vent
flue, or room venting ductwork.
Seek professional advice before
connecting an exhaust hood vent to
an existing, inactive chimney or vent
flue.
Important!
If the ductwork runs through rooms,
ceilings, garages, etc. where
temperature variations exist, it may
need to be insulated to reduce
condensation.
30

Condensate trap

optional accessory
In some cases, a condensate trap may
also be required to collect and
evaporate any condensate which may
occur. This optional accessory is
available for ducts 5" (125 mm) and
7
5
/
" (150 mm) in diameter.
8
When installing a condensate trap,
ensure that it is positioned vertically
and if possible directly above the
exhaust outlet. The arrow on the
casing shows the venting direction.