Miele T 1576 기술 정보 - 페이지 20

{카테고리_이름} Miele T 1576에 대한 기술 정보을 온라인으로 검색하거나 PDF를 다운로드하세요. Miele T 1576 42 페이지. Vented dryer
Miele T 1576에 대해서도 마찬가지입니다: 사용 설명서 (40 페이지), 사용 설명서 (40 페이지)

Miele T 1576 기술 정보
Technical Information
The condenser system draws air from outside the appliance via the condensate
fan (Item 8). The outside air passes through the heat exchanger in a 90° direction
from the drying air. The temperature difference between the two allows moisture
(condensation) to form on the heat exchanger. As the moisture level increases,
water droplets collect in a trough.
When the condensed water accumulates to a specific value, the condensate float
switch activates. The electronic switches on the condensate pump (Item 10) and
the water is pumped to the condensed-water drawer (Item 1). Should the
condensed-water drawer become full prior to the end of a cycle, the “"Empty out
container”" LED will light up and the program will stop.
Note:
Condenser dryers can be configured with an optional drain line. With this
configuration the condensed water is pumped directly into the drain, so
emptying the condensed-water drawer is not necessary.
4.3

Fan Motor (M5) Assembly

Figure 4-3: Fan Motor Assembly

1 Pulley/belts
2 Motor bracket
3 Motor start capacitor
4 Fan motor (120VAC)
5 Fan housing cover
6 Fan impeller
7 Fan housing
8 Motor assembly slide track
20
T 15xx Dryers