The burner does not ignite after several attempts.
Possible fault
Disconnect the appliance from the electrical supply for a few seconds. If the
problem persists, check if:
– The burner is assembled incorrectly.
– The gas valve is closed.
– The burner is wet and soiled.
– The flame slits are dry and
unblocked
The flame goes out after being lit.
Possible fault
The flames are not touching the ignition safety control. Check if:
– The burner is assembled incorrectly.
– There is no soiling on the ignition
safety control.
The flame appears different than usual.
Possible fault
The burner is assembled incorrectly.
The flame goes out during operation.
Possible fault
The burner is assembled incorrectly.
Frequently asked questions
Solution
– Reassemble the burner as shown in
"Cleaning and Care - Burners".
– Open the gas valve.
– Clean the burners. See "Cleaning
and Care".
– Dry the igniters.
Solution
– Reassemble the burner as shown in
"Cleaning and Care - Burners".
– See "Cleaning and Care".
Solution
Reassemble the burner as shown in
"Cleaning and Care - Burners".
Solution
Reassemble the burner as shown in
"Cleaning and Care - Burners".
19