Problem
Packings are failing
Scored, damaged, or worn plungers
freq entl or
frequently or
Abrasive material in fluid being pumped
prematurely
prematurely
Inlet water temperature too high
Overpressurizing pump
Excessive pressure due to partially
plugged or damaged tip
Pump running too long without spraying
Running pump dry
Strong surging at inlet
Foreign particles in inlet or discharge
and low pressure on
valve or worn inlet and/or discharge
discharge side
valves
Cause
Solution
Install new plungers.
Install proper filtration on pump inlet plumbing.
Check water temperature. It should not
exceed 160_F (70_C).
Do not modify any factory–set adjustments.
Clean or replace tip. See Installing and
Changing Spray Tips, Operating Instruction
manual 309886.
Never run pump more than 10 minutes without
spraying.
Do not run pump without water.
Clean or replace valves.
7
309887