5-7. Connecting 120 Volt Input Power

.
A complete Parts List is available at www.MillerWelds.com
!
Installation must meet all National and
Local Codes − have only qualified
persons make this installation.
!
Special installation may be required
where gasoline or volatile liquids are
present − see NEC Article 511 or CEC Sec-
tion 20.
See rating label on unit and check input voltage
available at site.
.
The Auto-Line circuitry in this unit automati-
cally links the power source to the primary
voltage being applied, either 120 or 240
VAC.
For 120 volts AC input power, a 15 or 20 ampere
individual branch circuit protected by time-delay
fuses or circuit breaker is required.
1
Multi-Voltage Plug And Power Cord
Connector (NEMA Type 5−15P Plug
Shown)
For multi−voltage plug connections, see Section
5-6.
2
Receptacle − NEMA Type 5−15R
(Customer Supplied)
1
Input6 2011−03 Ref. 253 558-A
OM-253 555 Page 17
2