Miller XT30C 매뉴얼 - 페이지 28
{카테고리_이름} Miller XT30C에 대한 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Miller XT30C 40 페이지.
Miller XT30C에 대해서도 마찬가지입니다: 소유자 매뉴얼 (40 페이지)
![Miller XT30C 매뉴얼](/uploads/products/server2/3571409/3571409.jpg)
SECTION 6 − MAINTENANCE & TROUBLESHOOTING
6-1. Routine Maintenance
n = Check
* To be done by Factory Authorized Service Agent
Each
Use
n Gas/Air Pressure
Every
Week
n Shield Cup Shutdown
System
l Damaged Or Unreadable
Every
Labels
3
Months
n l Torch Body, Cable
Every
OR
6
Months
~ Inside Unit
6-2. Shield Cup Shutdown System
.
OM-254 449 Page 24
Z = Change
~ = Clean
n Torch Tip, Electrode,
And Shield Cup
~ Air Filter/Regulator
Power must be reset whenever the cup shutdown system
is activated. Always turn Off power when changing or
checking consumables. Do NOT overtighten torch
shield cup. Gently finger tighten cup onto torch.
1
l = Replace
l Cracked Parts
n l Gas/Air Hose
!
Disconnect power
before maintaining.
.
Maintain more often
during severe conditions.
Reference
Section 3,
6-3
Section 6-2
Section 6-3,
7
1
Torch Shield Cup
Turn Power On and loosen shield
cup. If shutdown system works
properly, Cup light comes on. If not,
immediately turn Off power and
have Factory Authorized Service
Agent check unit.
If system works properly, retighten
cup and reset power.
Ref. 253 554-A