5-5. Electrical Service Guide

Failure to follow these electrical service guide recommendations could create an electric shock or fire hazard. These recommenda-
tions are for a dedicated circuit sized for the rated output and duty cycle of the plasma cutter.
Input Voltage (V)
Input Amperes (A) At Rated Output
Max Recommended Standard Fuse Rating In Amperes
Min Input Conductor Size In mm
Max Recommended Input Conductor Length In Meters
Min Grounding Conductor Size In mm
Elec Serv 2011−08
5-6.
Selecting Extension Cord (Use Shortest Cord Possible)
.
When calculating max. cord length, remember to include conductor length from line disconnect device to input power receptacle.
Single Phase AC
Input Voltage
230 VAC
*Conductor size is based on maximum 3% voltage drop

5-7. Connecting Input Power

!
Installation must meet all National
and Local Codes − have only
qualified
persons
make
installation.
!
Special installation may be required
where gasoline or volatile liquids
are present − see NEC Article 511 or
CEC Section 20.
OM-256 118 Page 18
.
A complete Parts List is available at www.MillerWelds.com
2
2
.
The Auto-Line circuitry in this unit
automatically links the power source to
this
the primary voltage being applied.
See rating label on unit and check input
voltage available at site.
Conductor Size − mm
1.5
Maximum Allowable Cord Length in meters
24
1
1
Power Cord
2
Receptacle (Customer Supplied)
Connect plug to receptacle.
50/60 Hz Single Phase
230
14.3
A 10 ampere individual
circuit protected by
time-delay fuses or circuit
breaker is required.
See Section 4-1
1.5
24
1.5
2
*
2
Ref. 257 916-A