Miller S-74 MPa Plus 소유자 매뉴얼 - 페이지 33

{카테고리_이름} Miller S-74 MPa Plus에 대한 소유자 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Miller S-74 MPa Plus 48 페이지.

Miller S-74 MPa Plus 소유자 매뉴얼
8-3.

Setting A Start Sequence In Synergic Pulse

To turn on a Start sequence, press the
START button. The START ON INDICATOR
will illuminate indicating Start is active.
To turn off the Start sequence, press the
START button. The START ON INDICATOR
will turn off indicating Start is inactive.
The factory default mode for Start is
(AUTO). The (AUTO) setting has pre-
set parameters. Start can also be set
to (MAN) for manual settings. The
Start mode can be changed in the
START MENU.
To enter the START MENU press and hold
the START button until the START MENU
INDICATOR illuminates.
Rotate the LEFT ADJUST Knob to select
different menu items shown in the LEFT
DISPLAY. Rotate the RIGHT ADJUST Knob
to change menu item values shown in the
RIGHT DISPLAY.
To exit the START MENU, press and re-
lease the START button.
Items that can be adjusted in this menu are:
Start Mode (STRT) - Sets the Start Mode to
(AUTO or MAN). When the Start mode is set
to (AUTO), factory default parameters are
used. The (AUTO) parameter values appear
in the menu but are not adjustable. When
the Start Mode is set to (MAN), each of the
parameters are adjustable.
Start Wire Feed Speed (WFS) - Sets the
wire feed speed used during the Start Time.
This setting is a percentage of the wire feed
speed the unit is set to for welding. Range of
this setting is from (X0.5 to X2.50). Example:
If the weld wire feed speed is 200 and WFS
is X1.50, the Start wire feed Speed is 300.
Start Arc Length (ARC. L) - Sets the arc
length longer or shorter during the Start
Time. This setting is a percentage of the arc
length the unit is set to for welding. Range of
this setting is from (X0.50 to X1.50). Exam-
ple: If the weld arc length is set to 50 and
ARC.L is X0.50, the Start Arc Length is 25.
When the PULS option in the SETUP
MENU LEVEL 2 is set to VOLT, the
Start Arc length setting will be re-
placed by the Start Voltage (VOLT)
setting.
Start Voltage (VOLT) - Sets the voltage dur-
ing the Start Time. Range of this setting
varies with the selected wire and gas pro-
gram in the PULSED MIG process. With the
weld process set to PULSED MIG, the Start
Voltage setting will change if the wire and
gas program selection is changed.
OM-273244 Page 23
Start Time (TIME) - The amount of time the
wire feed speed is active at the Start setting.
Range of this setting is from (0.1 to 0.5)
seconds.
Start Ramp Time (RAMP) - The amount of
time it takes to transition from the Start to
the weld wire feed speed setting. Range of
this setting is from (0.1 to 5.0) seconds.
OM-289404 Page 27