Miller SUITCASE 12RC 소유자 매뉴얼 - 페이지 23
{카테고리_이름} Miller SUITCASE 12RC에 대한 소유자 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Miller SUITCASE 12RC 40 페이지. Wire feeder with gun and meters
Miller SUITCASE 12RC에 대해서도 마찬가지입니다: 사양 (2 페이지), 소유자 매뉴얼 (36 페이지), 소유자 매뉴얼 (40 페이지)
6-2. Setting Digital Meter Board PC4 DIP Switches
Wire Speed
Settings
Wire Speed In
Inches Per Minute
Wire Speed In
Meters Per Minute
1
2
3
.
Meter DIP switches are factory set
to display voltage using 14-pin
feedback. Meter hold feature is
factory set to off position.
Shows switch in ON/DOWN (closed) position.
Shows switch in OFF/UP (open) position.
Shows switch does not affect this function.
Voltage Display
Settings
Display Volts
Using Sense Lead
Display Volts
Using 14-Pin
1
Front Meter Panel
2
S1 DIP Switch
3
S2 DIP Switch
If the DIP switches are set to a Meter
Hold (ON) position, the meter value
will hold 5 seconds after gun is trig-
gered. The meter value will continue
to hold for 8 seconds after trigger is
released or until gun is re-triggered.
Amperage Display
Settings
Display Amps Using
Current Sensor
Display Amps
Using 14-Pin
Meter Hold
Settings
Meter Hold ON
Meter Hold OFF
Ref. 803 141
OM-263984 Page 19