Miller 1009728 사용자 지침 - 페이지 6

{카테고리_이름} Miller 1009728에 대한 사용자 지침을 온라인으로 검색하거나 PDF를 다운로드하세요. Miller 1009728 48 페이지. Single anchor point

Miller 1009728 사용자 지침
Once the job is finished, unhook your connector. Pull on the QUICKLOCK trigger to deblock the cone and withdraw your
apparatus. If the QUICKLOCK remains blocked, introduce a thin metallic rod and tap gently to push the blocking cone
backwards.
Min. thickness of support
Drilling diameter
Min. drilling depth
CLEARANCE
Before each use, make sure there is sufficient clearance under the user's feet to avoid collision with the structure or
the ground. Considering a 100 kg weight and a fall factor of 2 (least favourable case), clearance D is arrest distance
H (2L+1.75m) plus an additional distance of lm. (except in particular cases: see specific manual). When possible, the
Quicklock located above the user will minimize the height of the free fall.
PERIODIC EXAMINATION
These instructions must be kept with the product. Fill in the identification sheet while entering information about mark-
ing. This periodic examination is designed to check the efficiency and strength of the equipment and is indispensable to
protect the user. This equipment must be examined at least once a year, by a competent person and in strict compliance
with the manufacturer's instructions; the verification to be recorded on the attached sheet and by placing a sticker on
the product The frequency of the examination may need to be increased according to the regulations,for intensive use
or under harsh environmental conditions. The product markings must be legible.
MAINTENANCE AND CLEANING:
Protect from any heat source. Protect against chemical products which can harm the removable anchor. Protect against
sharp edges, rubbing and shocks during use and transport Clean with compressed air. Store away from light and sig-
nificant heat sources.
FIELD OF UTILISATION:
• HIGH LEVEL WORK
• HORIZONTAL SURFACE
6
CORRECT
SETTING DATA
110
Embedding depth
18
Min. interaxial between 2 anchor points
90
Min. distance between free edge and anchor point
• VERTICAL SURFACE
• INCLINED SURFACE
INCORRECT
80
188
155