Thank you for your purchase of this Aquaphor RO. With proper installation and maintenance, this system will
provide you with premium quality drinking water. The technology used in the Aquaphor RO enriches the filtered
water with minerals in controlled quantities.
This water is highly beneficial for the body as it helps to normalize the physiological processes.**
If you have any questions or concerns, please contact our customer service department at +1 (855) 855 2299
or email [email protected], [email protected]. We are always happy to answer any questions you
may have regarding our product.

Introduction

Aquaphor RO operates by removing contaminants from water at the molecular level. By using your household
water pressure to squeeze the water against a special membrane, the water molecules are separated from any
impurities that exist.
Rejected dissolved solids are automatically rinsed away through the drain leaving you with only high-quality,
delicious water for your use.

1. Operational parameters

Operating temperatures:
Operating pressure:
Dimensions (length х height х width):
Maximum flow rate membrane cartridge
(water temperature +25 °С (77 °F)
with a constant pressure of 0.4 MPa
(4 bar / 58.02 psi)
Cleaned water to drained water ratio
(water temp. no less than +20 °С / 68 °F)
Mass no more than
pH parameters:
Iron:
TDS (Total Dissolved Solids):
Turbidity:
Hardness:
* This statement has not been evaluated by the United States Food and Drug Administration.
AQUAPHOR RO-101S, RO-102S
Maximum 38 ºC (100.4 ºF)
Maximum 0.63 MPa
(6.3 bar / 91.4 psi)
The operating pressure in your home should be tested over a 24 hour
period to attain the maximum pressure. If it is above 0.63 MPa (6.3 bar
/ 91.4 psi), then a pressure regulator is necessary, and will be required.
371 х 420 х 190 mm
For Aquaphor RO-101S – 50 GPD
For Aquaphor RO-102S – 100 GPD
1:4-1:6
6.2 kg / 13.66 lbs
Maximum 10
Maximum 0.3 ppm
Maximum 2000 ppm
Maximum 1 NTU
Recommended water hardness should not exceed 350 ppm as CaCO
(20.5 grains per gallon). The system will operate with hardness over
350 ppm (20.5 gpg), but the membrane cartridge life may be shortened.
The addition of a water softener may lengthen the membrane cartridge
life.
Minimum 5 ºC (41 ºF)
Minimum 0.19 MPa
(1.9 bar / 27.6 psi)
Minimum 4