Diamond B/2P-E/2P 매뉴얼 - 페이지 11
{카테고리_이름} Diamond B/2P-E/2P에 대한 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Diamond B/2P-E/2P 17 페이지.
3. CONVERSION FOR OPERATION WITH A DIFFERENT TYPE OF GAS
Shut the gas valve upstream of the unit
3.1
Replacing the nozzle of the main burner
- Open the cabinet door and remove the oil containers.
- Press the primary air regulator into the venturi tube.
- Using a 12 mm spanner, unscrew the nozzle and replace it with a suitable one for the selected gas type, as indicated in
Table 2 (p10).
3.2
Setting the primary air at the main burner
- Start the unit according to the user instructions.
- Check for leaks using soapy water. Ignite the pilot flame according to instructions and check it.
- To check the primary air setting at the main burners, the "X" clearance must be set exactly as shown (see image).
The primary air is properly set when the flame does not detach itself when the burner is cold and does not return when
the burner is hot.
- Check the ignition and flame compliance on maximum.
11