Diamond B/2P-E/2P 매뉴얼 - 페이지 9
{카테고리_이름} Diamond B/2P-E/2P에 대한 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Diamond B/2P-E/2P 17 페이지.
2.12 Adjusting the settings
After all the connections have been made, the unit's settings can be adjusted.
Important: first, make sure that there are no leaks at the joints.
1. Calibrating the burners is limited to the injector, if it not intended for the type of gas that you will use. If the utilised gas
is different from the type indicated on the data plate (see p. 3), please proceed as shown in the following picture.
NEVER SET A PRESSURE VALUE THAT IS HIGHER THAN
SPECIFIED !!!!
2. In case of problems with the pilot burner, such as the flame often going out, adjust the pilot light as illustrated in the
picture.
1. Remove the cap using a flat-
blade screwdriver
2. Adjust the pilot light
9