Ex. 3
• Install any one of the three fountain heads onto the top
riser by simply pressing it over the end of the riser. It is
held in place by friction (Ex. 5).
• The AquaJet pump is designed to be submerged directly
into the pond. If using the diverter valve to send water to
any additional filters, fountains, or waterfalls, maximize
pond circulation by locating the AquaJet pump as far
away as possible from the location of the water entering
back into the water feature (Ex. 6).
• If the pump is not on a level base, loosen the riser stem
collar and adjust the orientation of the riser stem to keep
the fountain head vertical (Ex. 7).
Ex. 6
• If not using the fountain kit, the diverter valve or the
multi-hose adapter can be used to supply water to an
accessory such as a spitter, external filter, or waterfall
(Ex. 8).
• If using the diverter or multi-hose adapter to supply
water to an additional filter, fountain, or waterfall, it is
recommended to NOT position the pump in the deepest
portion of the pond. This will protect the fish by preventing
the pond from completely draining in case of leak in the
plumbing or filter, fountain, or waterfall. Bricks or stones
can be used if needed to raise the pump off the bottom.
• Connect pump to an outlet that is protected by a ground
fault interrupter. Once the pump is running and water
circulating through the filter(s) or waterfall, check for any
aquascapeinc.com |
CAN (866) 766-3426 |
Accessory
Diverter
Valve
Side Valve
Ex. 4
Ex. 5
Ex. 7
US (866) 877-6637
fitting or waterfall leaks where the external connections are
made (Ex. 9).
Ex. 8

General Maintenance

• Fountain Height
– Pump size, as estimated in the earlier table
– How deep the pump is positioned in the water; lowering
the pump increases the flow since the discharge is also
lowered
– The two valve adjustments on the diverter valve (see
information above)
• Pump Screen Cleaning
– To maintain the correct flow and fountain head patterns,
both the fountain heads and the pump screens will
require occasional cleaning.
• Pump Cage
– Do not remove the upper or lower pump cage while
operating the pump. Failure to operate the pump without
the filter cage or operating the pump with a broken cage
will allow large debris to enter the pump causing the
pump to fail voiding the warranty.
• Pump Cage Cleaning
– We recommend inspecting your AquaJet on a regular
basis to make sure it is functioning properly. If you notice
the water flow rate diminish it may be due to the pump's
filter cage becoming clogged with debris. Always
disconnect the power before performing maintenance
on the pump. In many cases the clogged filter cage
can be cleaned by simply
reaching in the pond or
pulling the pump out of
the water and removing
debris from the filter cage.
The pump can also be
removed from the pond
and the debris stuck to
the pump filter cage can
be removed or sprayed off
with a garden hose (Ex. 10).
• Pump Leveling
– If the pump is not on a level base, loosen the riser stem
collar and adjust the orientation of the riser stem to keep
the fountain head vertical.
Ex. 9
Ex. 10