Using fuel of large humidity causes his larger waste as well as causes the
condensations of water steam inside fireplace. Condensate accelerates the
corrosions of steel exchanger of fireplace.
To get wood humidity about 20% near natural drying it should be seasoned
where through the least 18 months. Near seasoning of wood by period since 6
months till year the humidity of wood will be on level 45% to 30%.
The diameter of logs of wood should carry out 10-20 cm. and their length should
make possible them free loading to chamber.
4.2) Burning up SPECTRA:
Before first lighting as well as after long term of non-use of fireplace, before
accession to use should check the patency of channels of fireplace and
chimney as well as the heating factor in installation.
1) Open the fire-doors and throttles of flue gases (pressing levers 5)
2) Set the initially air inlet (lever 7).
3) On grill to arrange the kindling-fuel ( the paper or kindling-fuel grilowa)
and at the top little twig and pieces of wood about diameter 3-5cm.
4) Fire the paper and close fire-doors.
5) When burning fuel creates the shell of heat unlock fire-doors to supply the
chamber with chunks of wood or briquette.
6) Close the fire-doors and regulate the process of combustion with throttles
of flue gases and air.
a. As well as the throttles are more open the chimney draught it larger
and the combustion is more intensive (larger power)
b. As well as the throttles are more closed the chimney draught is
smaller and the combustion is freer (smaller cardinality).
c. The protrusion the mechanism of throttle of flue gases causes her
lock and inserting opening.
d. The air choke is open when lever is in horizontal position and closed
when it is in perpendicular position.
7) Fuel make-up can happen only at that time when fires over heat start
burning down.
gases and we unlock fire-doors then slow. We supply fuel and close fire-
doors. We make the adjustment of draught.
We put, in aim to obtain the maximum power, to boiler 5-7 chunks of about
diameter from 10 cm. to 20 cm and we unlock the throttles of flue gases and
air entirely.
To get the lower power of fireplace we should charge smaller quantity fuel
and adjust throttles in such way to fire was not too intensive.
At first burning up in fireplace water can show inside fireplace ("perspiration
fireplace"). This normal effect is because the temperature of flue gases at
cold fireplace can fall below temperature of dew and the condensation of
water steam follows. Effect goes out after heating fireplace and installation.
- 8 -
We close the air choke, we unlock the throttle of flue