Inspect the purchased pump for damage or leakage during
transportation. And make sure all bolts and nuts are tightened
properly.
A typical installation diagram is shown below. Please
follow the given installation precautions before and during
installation.
Pump should be positioned as shown in figure-A. Pump
should be installed in a protected environment, not
exposed to weather. Provide sufficient space around the
pump for motor cooling and accessibility, refer figure-B.
5
2
1
3
No.
1
Pipe support: Support piping system properly to avoid stresses on connections.
Isolating valves: Install isolating valves for easy access- before the pump intake and after
2
the pump discharge.
Use flexible piping on both input and output sides of the pump to reduce vibration and
3
transmission of noise.
Check valves will prevent return flow of pumped liquid when pump is stopped, reducing
4
the danger of pump damage.
Control Panel: Use high quality components. Make sure that the panel conforms to local
5
standards and regulations.
6
Do not place elbows next to the pump intake and discharge.
If pump needs to be operated with isolating valve closed, install a by-pass line to avoid
7
damaging the pumping system.
INSTALLATION PRECAUTIONS
PRODUCT INSPECTION
TYPICAL INSTALLATION
4
2
3
A
6
1
Description
B
7