Aquatek ATAIOIF Series 운영 및 유지보수 매뉴얼 - 페이지 5

{카테고리_이름} Aquatek ATAIOIF Series에 대한 운영 및 유지보수 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Aquatek ATAIOIF Series 16 페이지. Chemical free iron & sulfer filter

A Control Valve
B Mineral Tank

About Your Filter

How Does my Sulfur and Iron Filter Work?
This filter uses a special blend of calcium, magnesium oxide
and sand that is highly effective for removal of hydrogen sul-
fide and iron. The filter uses an air chamber within the tank to
capture and oxidize the elements and then filter them through
the media bed. An automatic backwashing system will clean
the media of the sulfur and iron leaving the system clean, and
the water you drink odor free.
All Aquatek Iron Filters are comprised of two primary
components: (A) Control Valve, (B) Mineral Tank.
A. Control Valve: Your control valve automatically
performs the 3 primary operations which are com-
monly referred to as cycles. These operations/cycles
are:
1. Pre-Treatment Oxidation: Air is injected into the
mineral tank which causes contaminants in the
water to precipitate and settle out. Precipitated
contaminants are much larger and clump to-
gether so they can be removed through filtration.
2. Service / Filtration: The oxidized water is now
flushed through the media bed comprised of Ze-
oLite
mechanically strains the contaminants like iron,
manganese, & hydrogen sulfide.
3. Backwash: Once the media bed has reached its
predetermined limit of filtration it cleans and re-
plenishes itself through backwashing. Backwash-
ing is a forceful flush that removes the filtered
contaminants and then flushes then down the
drain.
B. The Mineral Tank: The mineral tank contains the
filtration media and is where the the treatment of
the water takes place during the 3 stages mentioned
above.
UNITED WATER INC.
A
AtAIOIF-S
quAtek
erIeS
(see pg 4) and gravel underbedding which
1
u
G
Ser
uIde
5