HP StorageWorks 9100 - Extreme Data Storage System 사용자 설명서 - 페이지 24
{카테고리_이름} HP StorageWorks 9100 - Extreme Data Storage System에 대한 사용자 설명서을 온라인으로 검색하거나 PDF를 다운로드하세요. HP StorageWorks 9100 - Extreme Data Storage System 50 페이지. Hp storageworks 3gb sas bl switch installation instructions (496788-002, march 2009)
HP StorageWorks 9100 - Extreme Data Storage System에 대해서도 마찬가지입니다: 지침 (4 페이지), 설치 지침 (3 페이지)

Error codes
Table 4 Error codes
Error code
Cn01
Fn00 – Fn67
Hn00 – Hn29
Hn30
Hn31–66
Hn67
Fan module LEDs
Item
Description
1
Fan module LED
24
LED descriptions
Description
Configuration error—Hardware not
supported
Firmware error
Hardware error—Controller error
Hardware error—Fatal ECC error
Hardware error—Controller error
Hardware error—SAS expander error
Status
Green—Normal operation
Blinking amber—Fan fault condition exists
Off—Fan unseated from connector or has failed
Required action
Log error, check hardware and cable
connections.
Log error, restart enclosure. If error persists,
contact HP support.
Log error, contact HP support, replace
controller.
Log error, contact HP support, replace
cache module.
Log error, contact HP support, replace
controller.
Log error, contact HP support, verify