Alpha ESS SMILE-BAT-10.1P 빠른 설치 매뉴얼 - 페이지 6

{카테고리_이름} Alpha ESS SMILE-BAT-10.1P에 대한 빠른 설치 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Alpha ESS SMILE-BAT-10.1P 7 페이지.

Alpha ESS SMILE-BAT-10.1P 빠른 설치 매뉴얼
Configuration with GoodWe Inverter
1. If there is only one BAT, DIP switch of BAT should be set as below:
2. If there are two or more than two BAT, DIP switch of BAT should
be set as below:
If there are two or more than two BAT, after connecting the
power cables, please refer to the following steps:
Only connect the communication cable between batteries at the
first, and turn on the batteries.
Wait until batteries get to work mode (The green light flashes
every 10 seconds) and then connect the communication cable
between BAT and INV.
Configuration with Inverter
GoodWe SBP /AlphaESS SMILE 5 series
The communication cable between INV and BAT is regular net cable.
1. If there is only one BAT, DIP switch of BAT should be set as below:
2. If there are two or more than two BAT, DIP switch of BAT should
be set as below: