6. Accessories(optional) and Software
Software
(1)Solar station Monitor
 Download software
www.epsolarpv.com/en/index.php/Technical/download——PC Software for the Solar
Charge Controller
(2)Mobile APP software setting
 Download software
www.epsolarpv.com/en/index.php/Technical/download——Andriod
Li-Battery Solar Charge Controller
 IPhone——APP Store——EPEVER
※Specific instructions refer to the list of accessories and software.
7. Protection
Protection
Conditions
PV Reverse
When the battery is correct connecting, the
Polarity
PV can be reversed.
Battery
When the PV is not connecting, the battery
Reverse
can be reversed.
Polarity
Battery Over
The battery voltage reaches to the OVD
Voltage
Battery Over
The battery voltage reaches to the LVD
Discharge
Temperature sensor is higher than 65℃
Battery
Overheating
Temperature sensor is less than 55℃
Temperature sensor is less than the low
Lithium battery
temperature value(Default 0℃)
Low
Temperature sensor is higher than the low
Temperature
temperature value(Default 0℃)
Load current ≥2.5 times rated current
One short circuit, the output is OFF 5s;
Two short circuit, the output is OFF 10s;
Load Short
Three short circuit, the output is OFF 15s;
Circuit
Four short circuit, the output is OFF 20s;
Five short circuit, the output is OFF 25s;
Six short circuit, the output is OFF
Lithium battery
Limit current temperature
limit current in
T1>T2>T3>T4>T5>T6
low
Limit current I1>I2>I3>I4>I5>I6
temperature
8. Technical Specifications
Item
Nominal system voltage
Battery input voltage range
Rated charge current★
Rated charge power
Max. PV open circuit voltage
MPP Voltage range
Max. output current
Max. output power
Output voltage range
Load open circuit voltage
Load over voltage protection
Maximum output efficiency
Output current control accuracy
Battery Type
Equalize Charging Voltage
Boost Charging Voltage
Float Charging Voltage
Low Voltage Reconnect Voltage
Low Voltage Disconnect Voltage
Boost Charging Voltage
Low Voltage Reconnect Voltage
Low Voltage Disconnect Voltage
Self-consumption
Temperature compensation coefficient
Communication
Working environment temperature
Enclosure
Overall dimension
Mounting hole size
Mounting dimension
Power cable
Net weight
★The controller has the limit charge current function, the current can be set via the APP software and RC10.
BEIJING EPSOLAR TECHNOLOGY CO., LTD.
APP
Status
The controller is not
damage
Stop charging
stop discharging
Output is OFF
Output is ON
Lithium battery stop
charging/discharging
Lithium battery
charging
Output is OFF
Clear the fault:
Restart the controller
or wait for one
night-day cycle (night
time>3 hours).
When the temperature
is lower than T1, the
charging current is I1;
when the temperature
is lower than T2, the
charging current is I2;
and so on. However,
when the temperature
rises gradually from T4
to T1, it is performed at
I4.
Tracer2606BPL
Tracer3906BPL
12/24VDC Auto(Lithium battery do not automatic identification system voltage)
10A
15A
130W/12V;260W/24V 195W/12V;390W/24V 260W/12V;520W/24V 130W/12V;260W/24V
58V( at minimum operating environment temperature )
46V( at 25℃ environment temperature )
( Battery voltage+2V)~36V
3.3A
4.5A
100W
130W
( Max. battery voltage+2V)~58V
58V
63V
Lead-acid battery: Sealed(Default) / Gel / Flooded/User; Lithium battery:LiFePO4/ Li-NiCoMn/User
124×89×30mm
150×93.5×32.7mm
88×76mm
120×83mm
PV/BAT:14AWG(2.5mm
0.54kg
0.73kg
3
Tel:+86-10-82894112 / 82894962 Website:www.epsolarpv.com/www.epever.com
9. Troubleshooting
Faults
LED Charging
indicator turn off
during daytime
when sunshine falls
on PV modules
properly
No LED indicator
Battery LED
indicator green fast
Flashing
Battery LED
indicator red
for
the
Battery LED
indicator red
flashing
Powering on
normally, the load is
off
The dimming
function is invalid
①When the battery is over discharged, the battery indicator will be red and the load will
be off all the time before the voltage is more than the Low Voltage Reconnect Voltage
(LVRV). In order to judge the system is normal or not, firstly measuring the battery
voltage whether is more than LVRV, if not, restarting the controller to detect the load
whether it is normal.
NOTE: The LVRV can be set, but it must pay more attention that it maybe
damages the battery if the LVRV is too low.
10. Disclaimer
This warranty does not apply under the following conditions:
 Damage from improper use or use in an unsuitable environment.
 PV or load current, voltage or power exceeding the rated value of controller.
 The controller is working temperature exceed the limit working environment
temperature.
 User disassembly or attempted repair the controller without permission.
 The controller is damaged due to natural elements such as lighting.
 The controller is damaged during transportation and shipment.
Tracer5206BPL
9~32VDC
20A
6.6A
200W
96%
≤2%
Sealed :14.6V/Gel:No / Flooded:14.8V/User:9-17V (×2/24V)
Sealed :14.4V/Gel:14.2V/Flooded:14.6V/User:9-17V (×2/24V)
Sealed/Gel/Flooded:13.8V/User:9-17V (×2/24V)
Sealed/Gel/Flooded:12.6V/User:9-17V (×2/24V)
Sealed/Gel/Flooded:11.1V/User:9-17V (×2/24V)
LiFePO4:14.5V/ Li-NiCoMn:12.5V / User:9-17V (×2/24V)
LiFePO4:12.8V / Li-NiCoMn:10.5V / User:9-17V (×2/24V)
LiFePO4:11.1V / Li-NiCoMn:9.3V / User:9-17V (×2/24V)
≤15mA/12V;≤22mA/24V
-3mV/℃/2V(Lithium battery don't have temperature compensation coefficient)
RS485
-40℃~+60℃
IP67
153×105×52.1mm
Φ3.5mm
120×94mm
2
2
);LOAD:18AWG(1.0mm
)
1.18kg
Possible reasons
PV
Confirm that PV and battery wire
array disconnection
connections are correct and tight
Measure battery voltage with the
Battery voltage maybe
multi-meter. Min.9V can start up the
less than 9V
controller
Check if battery voltage is higher
Battery over voltage
than OVD, and disconnect the PV
When the battery voltage is restored
Battery
to or above LVR point (low voltage
reconnect voltage), the load will
over discharged
recover
The controller will automatically turn
the system off. But while the
Battery Overheating
temperature decline to be below 50
º C, the controller will resume.
①The connecting
① Check the connecting cable.
wires are error or
② Check the load's mode and
virtually connected
parameters.
②Load mode is not
③The voltage of LED light is not
appropriate.
within the output voltage range of
③This controller does
controller.
not match with the LED
④Check the connecting cables and
light.
LED light.
④Output short circuit.
The controller does not
①Replace the LED light
match with the LED
②Reduce system rated voltage
light source. This
grade and replace the product
product is a step-up
model
voltage control, If input
For example 24V system change to
voltage is lower than
12V system, and replace the
the rated voltage, it is
corresponding controller
not working.
Tracer2610BPL
Tracer3910BPL
10A
15A
195W/12V;390W/24V
95V( at minimum operating environment temperature )
92V( at 25℃ environment temperature )
( Battery voltage+2V)~72V
3.3A
4.5A
100W
130W
( Max. battery voltage+2V)~80V
80V
100V
124×89×30mm
150×93.5×32.7mm
88×76mm
120×83mm
PV/BAT:12AWG(4mm
0.54kg
0.73kg
Any changes without prior notice! Version number:V2.0
4
Troubleshooting
Tracer5210BPL
20A
260W/12V;520W/24V
6.6A
200W
153×105×52.1mm
120×94mm
2
2
);LOAD:16AWG(1.5mm
)
1.18kg