Power Quality
The lighting circuits shall have surge protection. If you require assistance in checking your power system or designing or
implementing solutions, contact Eaton's Electrical Engineering Services and Systems. Find more information at www.eaton.
com.
INSTALLATION INSTRUCTIONS
Step 1 – Mount The Luminaire
The first step is to attach the luminaire to the mounting structure. The mounting structure may be a light pole cross arm, an
indoor catwalk bracket, or other structural component that will hold the fixture in place. Refer to photometric drawings or
project Installation Drawings for luminaire installation locations and any additional mounting instructions.
It is the responsibility of the installer to verify that all proposed mounting structures including poles, cross arms,
catwalk brackets, and other mounting structures are certified to support the weight of the luminaires, withstand
wind loads, and meet all other applicable codes and regulations. FAILURE TO FOLLOW THIS WARNING MAY LEAD TO
DEATH, SEVERE INJURY, OR PROPERTY DAMAGE.
Do not suspend any luminaire by electrical or control wires, as these will not support the weight of the fixture,
resulting in the potential for the fixture to fall and cause damage or injury. FAILURE TO FOLLOW THIS WARNING MAY
LEAD TO DEATH, SEVERE INJURY, OR PROPERTY DAMAGE.
Equipment Required:
Mounting Hardware
●
●
Socket wrenches and/or crescent wrenches sized to fit mounting hardware
●
●
Cable ties or wire management – For outdoor installations use UV rated
●
●
Hardware Required
Mounting Hardware Required
Mounting hardware shall be stainless steel or other high-strength, corrosion-resistant material. Length of Hex bolt shall be
determined in the field; size the bolt appropriately to allow secure fastening of the luminaire to the mounting structure.
An impact driver may be used on mounting hardware while the power is off, but NEVER use any power tools on the
fixture while the power is on. The vibration caused by power tools may damage the fixture. FAILURE TO FOLLOW
THIS WARNING MAY LEAD TO LUMINAIRE INTERNAL DAMAGE AND FAILURE.
There are two different ways to mount the All Field fixture – Standard and Inverted. Standard mounting is when the luminaire
sits on top of the mounting structure, and Inverted is when the luminaire hangs from underneath the structure.
4
EATON
MN507001EN
Hex bolt
5/8"-3/4" (16mm-19mm)
Flat washers
5/8"-3/4" (16mm-19mm) ID
Hex Locknut
5/8"-3/4" (16mm-19mm)