3.0 Schematic Diagram
Battery Board
4#
Outlet Board
3#
Center detection
rod for alarm board
Main Control Board
4.0 Calibration
Calibration is a process that is used to correct for accuracy and/or functional errors above and beyond those stated in
published specifications. While Manual-leveling, Self-leveling, and Automatic-leveling (motor driven) devices have
different mechanisms that require calibration, there are similarities with optics that is consistent regardless of the leveling
mechanism. This section of the service manual discusses calibrations specific to the 40-6535. Each item discussed is
shown below.
4.1 Horizontal Mode Operation
4.1.1 Quantifying Accuracy Error
4.1.2 Characterize the type of error
4.1.2.1 Oblique/Inclination Error
4.1.2.1.1 Fine calibration via Remote control
Prepared By: Tim Wojo
Z
X
Y
Y
X
1#
+
Revision - Date: 0 – 20080430
40-6540 Service Manual
X and Y axis Leveling
servo-motors (located on
Leveling Module)
X, Y, and Z axis Leveling
sensors (located on 13-14)
Motor/Laser Assembly
Alarm Board
2#
5#
Key Pad Board
4.1.2.2 Taper/Cone Error
4.2 Vertical Mode Operation
4.2.1 Calibration
4.3 Alarm Adjustment
Page 6 of 13