ELECTRICAL CONNECTION

3.4 AC Wiring

1. Remove a length of 43mm of the cable jacket and strip the wire insulation to a length of
10mm.
2. Crimp the terminals as shown in the figure below.
3. The wiring is shown in the figure below.
3.1 Unlock instructions
09
10

3.5 Communication Connection

The communication between the EV Charger and EMS of the energy storage system is
RS485.
RJ45 PIN definition is as below:
RJ45
RS485
RS485
RS485
3.5.1 Communication Connection with SMILE-HV Series
EV AC Charger – SMILE-G3-EVCT11
PIN4
RS485-B
ESS– SMILE-HV Series
RJ45
PIN4
RS485-B
ESS– SMILE-G3 Series
RJ45
PIN4
RS485-B
Communication port of SMILE-HV Series
ELECTRICAL CONNECTION
PIN5
RS485-A
PIN5
RS485-A
PIN5
RS485-A
Communication Cable
(Self made)