PUMP INSTRUCTIONS
11
WARNING
Failure to heed these warnings may result in loss of load, damage to the press and/or failure resulting in property damage, personal or fatal injury.
This operating manual contains important details concerning the safe operation of this tool.
The user must read and understand these details before any use of the tool.
This manual must be retained for future reference.
1. BEFORE OPERATING PUMP, open petcock valve
(breather) located on TOP of pump assembly
by turning COUNTERCLOCKWISE.
DO NOT attempt to operate pump unless the BREATHER VALVE IS OPEN.
Valve is closed prior to shipping to prevent the loss of hydraulic fluid.
3. Insert pump handle into low pressure
cradle. Use the low pressure pump until ram
comes into contact with item to be pressed.
CP500 Operation Manual
This symbol alerts you to the possibility
of serious injury or death if instructions
are not followed.
Top view of pump
WARNING
B
A
4. Once ram is in contact with the item to be pressed,
insert pump handle into high pressure side. Using
the high pressure pump moves the ram less with
each stroke and requires less effort to apply pressure.
2. CLOSE the valve located on the FRONT
A : Low Pressure Cradle
B : High Pressure Cradle
5. To relieve pressure and retract ram, turn valve
of the pump assembly by turning CLOCKWISE.
CAUTION
HAND TIGHTEN VALVE ONLY.
Excess pressure could
damage the valve assembly.
located on FRONT of pump assembly ONE FULL
TURN COUNTERCLOCKWISE.
CAUTION
DO NOT TURN RELEASE VALVE
MORE THAN ONE FULL TURN
or equipment may be disabled.
9