ARCBRO Scout2 서비스 지원
{카테고리_이름} ARCBRO Scout2에 대한 서비스 지원을 온라인으로 검색하거나 PDF를 다운로드하세요. ARCBRO Scout2 4 페이지. How to solve machine does not arcing
Service Support Spirit
How to solve machine does not arcing—Scout2
Problem : The machine does not arcing,
Solution overview:
Problem analysis:
Test the plasma power source
Solution:The plasma and the machine are connected by four wires, They are: ARC Start, ARC
Start, ARC+ ARC-; as shown in the figure.
Short-circuit A and B of plasma power side, if arc start, the plasma power source is
ok, otherwise plasma power source problem;
NOTE: You can directly short-circuit the arcing signal on the plasma power supply.
Plasam
Take powermax45XP as an example:
Unique Solution
1. Power does not ARC start.
2. The machine does not signal arcing;
A
B
C
D
CNC
WWW.ARCBRO.COM