ayerbe AY - 1600 사용 설명서 - 페이지 17

{카테고리_이름} ayerbe AY - 1600에 대한 사용 설명서을 온라인으로 검색하거나 PDF를 다운로드하세요. ayerbe AY - 1600 19 페이지. Wet and dry vacuum cleaner

7. CARTRIDGE FILTER MAIN-
TENANCE
WARNING! Always disconnect the plug
from the wall outlet before removing the
tank cover.
NOTICE! This filter is made of high
quality paper designed to stop small
particles of dust. The filter should be used
for dry pick-up. A dry filter is necessary to
pick up dust as when the filter is wet, the
filter will clog quickly and be very difficult
to clean.
Handle the filter carefully when removing
it for cleaning or when installing it. Check
the filter for tears or small holes as even a
small hole can let dust pass through and
out of the cleaner. Do not use a filter with
holes or tears, replace it immediately.
Installing &Cleaning
7.1. Slide the cartridge filter down over
filter basket and push fully home.
(fig.1&2)
7.2. Place filter retainer on top of car
tridge filter.
7.3. Hold onto base of lid cage with one
hand and turn retainer clock wise
tighten.
7.4. When removing the filter for cleaning
hold the cartridge filter to take off
carefully avoid damage it. (fig.3)
7.5. Slide cartridge filter off filter cage.
7.6. Clean a dry filter by tapping it inside
a waste can.(fig.4)
7.7. Clean a wet filter by rinsing from the
inside. (fig.4)
7.8. When wet the cartridge filter should
be removed and allowed to air dry
for 24 hours before being refitted
onto the filter basket.

8. TROUBLESHOOTING

1.No power
supply.
Cleaner
2.Faulty
will not
power cable,
operate.
switch or
motor.
3.Container
full of liquid.
Dust
1.dust bag or
comes
cartridge
from the
filter missing
motor
or damaged.
cover.
There is a
Reduced
blockage in
efficiency
the nozzle or
and
hose,
increased
Or the
motor
container
inlet. Or dust
speed/vib
filter blocked
ration.
by fine dust.
- 17 -
1. Check power
supply – cord,
breakers, fuses.
2. Unplug and check
the
power cord. If
damaged,
have it repaired by a
professional.
3.Empty container.
1. Attach or replace
dust bag or cartridge
filter.
Check nozzle, hose
and
container inlets for
blockage. Take off the
filter
and clean it. Or install
new
cartridge filter.