Cres Cor AquaTemp CO-151-FWUA-12DX2081BC 설치, 운영 및 유지보수 매뉴얼 - 페이지 12

{카테고리_이름} Cres Cor AquaTemp CO-151-FWUA-12DX2081BC에 대한 설치, 운영 및 유지보수 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Cres Cor AquaTemp CO-151-FWUA-12DX2081BC 17 페이지. Humidity convection ovens

5925 Heisley Road • Mentor, OH 44060-1833
Drain water pan and clean interior of unit as per instructions in FL-2373-BC
Check hinges and latch and adjust as needed per instructions in FL-2373-BC
Check that meat probe does not have any fraying wires or exposed conductors .
Check that cooling fans are operating when unit is running at cooking temps .
They are controlled by a thermal switch and may not kick on until unit has been
IF OVEN GETS TOO HOT OR WON'T SHUT OFF, DISCONNECT
POWER AT BRANCH PANEL. DO NOT UNPLUG CORD!
1 . Cord is unplugged from wall outlet .
2 . Circuit breaker/fuse to wall outlet is blown .
NOTE: Vent fans will not operate until the control compartment requires ventilation to limit temperatures . Replacement
of electrical components must be done by a qualified electrician.
Call Toll-free: 877-CRES COR (273-7267) • Fax: 800-822-0393 • www.crescor.com
MAINTENANCE INSTRUCTIONS
HOW TO ADJUST THE DOOR LATCH:
1 . For vertical (up and down movement) adjustment:
a . Loosen (2) screws located in magnetic strike .
b . Move strike up or down for alignment to magnet on latch .
c . Tighten screws to secure
2 . For horizontal (greater or lesser magnetic draw) adjustment:
a . Loosen (4) screws in door latch .
b . Move latch forward or backward to adjust magnetism .
c . Tighten screws to secure .
Replace as needed .
operating for some time .
If unit is NOT working, first check the following causes:
Daily
Weekly
Monthly
WARNING
3. Switch is turned off.
4 . Fuse on back of unit is blown .
Convection
FL-2373-BC
Humidity Oven
Page 12 of 17
Rev. 1 (8/20)