Cres Cor KC-UA-11H 운영 및 유지보수 지침 매뉴얼 - 페이지 6

{카테고리_이름} Cres Cor KC-UA-11H에 대한 운영 및 유지보수 지침 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Cres Cor KC-UA-11H 10 페이지. Refrigerated cabinet

Cres Cor KC-UA-11H 운영 및 유지보수 지침 매뉴얼
KoldCube
3
Refrigerated Cabinet
Rev. 1 (7/19)
TROUBLE-SHOOTING GUIDE
Unit Condition:
Unit is plugged in. Switch is ON.
Failure
1. Pans do not fit perfectly in trans-
port angles
2. Power light off, cabinet does
nothing
3. Thermometer value is flashing.
Cabinet is Not Cooling:
Failure
1. Compressor not operating.
2. Evaporator fans not operating.
3. Condenser fan not operating.
4. Refrigerant loss.
NOTES:
1. For replacement of the electrical parts, refer to our list of authorized service centers (FL-1400).
Call Toll-free: 877-CRES COR (273-7267) • Fax: 800-822-0393 • www.crescor.com
FL-2379
Page 6 of 9
MAINTENANCE INSTRUCTIONS
TROUBLE-SHOOTING GUIDE
Probable Cause
1a. Misalignment
2a. Battery not charged.
3a. Cabinet is outside normal temperature. 3a. Allow cabinet to come to temp.
Probable Cause
1a. Sensor issue.
1b. Wiring issue.
1c. Compressor overheated.
1d. Component failure.
2a. Door open.
2b. Wiring issue.
2c. Door switch failure.
2d. Evaporator fan failure.
3a. Wiring issue.
3b. Condenser fan failure.
4a. Leak.
5925 Heisley Road • Mentor, OH 44060-1833
Fix
1a. Add or remove shim kit.
2a. Charge battery.
Fix
1a. Fix or replace.
1b. Fix or replace.
1c. Wait to cool.
1d. Replace.
2a. Close door.
2b. Fix or replace.
2c. Fix or replace.
2d. Replace.
3a. Fix or replace.
3b. Replace.
4a. Check system for leaks, recharge.