Unit Condition:
Unit is plugged in. Switch is ON.
Failure
1. Pans do not fit perfectly in trans-
port angles
2. Power light off, cabinet does
nothing
3. Thermometer value is flashing.
Cabinet is Not Cooling:
Failure
1. Compressor not operating.
2. Evaporator fans not operating.
3. Condenser fan not operating.
4. Refrigerant loss.
NOTES:
1. For replacement of the electrical parts, refer to our list of authorized service centers (FL-1400).
Call Toll-free: 877-CRES COR (273-7267) • Fax: 800-822-0393 • www.crescor.com
FL-2379
Page 6 of 9
MAINTENANCE INSTRUCTIONS
TROUBLE-SHOOTING GUIDE
Probable Cause
1a. Misalignment
2a. Battery not charged.
3a. Cabinet is outside normal temperature. 3a. Allow cabinet to come to temp.
Probable Cause
1a. Sensor issue.
1b. Wiring issue.
1c. Compressor overheated.
1d. Component failure.
2a. Door open.
2b. Wiring issue.
2c. Door switch failure.
2d. Evaporator fan failure.
3a. Wiring issue.
3b. Condenser fan failure.
4a. Leak.
5925 Heisley Road • Mentor, OH 44060-1833
Fix
1a. Add or remove shim kit.
2a. Charge battery.
Fix
1a. Fix or replace.
1b. Fix or replace.
1c. Wait to cool.
1d. Replace.
2a. Close door.
2b. Fix or replace.
2c. Fix or replace.
2d. Replace.
3a. Fix or replace.
3b. Replace.
4a. Check system for leaks, recharge.