RIGGING & MOUNTING
EN
Grouping of insert sets for CPL 25C +
Group A
A set of four M6 inserts on the rear, designed to be used with the Peavey Versamount 35 mounting ceiling and
wall-mount bracket. These are spaced apart side-to-side on the centers by 76 mm, and apart 108 mm
top-to-bottom on the centers, and the group of four is located centered on the rear side-to-side, and closer to the
bottom.
Group B
The M8 inserts at the center of the U-Bracket mounting plates on the top and bottom, normally used for the
U-Bracket retention, but can be used for safety chain/wire rope if necessary.
Group C
The M6 insert at the center of the rear of the cabinet is for use with a safety chain when using the other Groups A
or B, using the proper eyebolt.
NEVER use just one insert to fly a cabinet! Insert C can use just one for safety wire/chain attachment, as long as
there are at least two other inserts on a given cabinet used for primary suspension points.
For Group A, always use all four inserts of a given group as a set; NEVER use just one insert to fly a cabinet! The
four insert groupings are meant to have all four inserts used at once within group A.
For Group B, always use both inserts with the appropriate hardware to mount a model specific Crest Audio
U-Bracket. These inserts can also be used, if necessary, as safety points for a chain or rope attachment point when
other mounting methods are being used.
5