RIGGING & MOUNTING
Specifications for insert mating hardware
Group A should use an M6, grade 8.8 or better, 1.0 mm per thread, metric bolt, that does not penetrate the cabinet
past the cabinet surface more than 20 mm (approximately 3/4"). When using a Peavey Versamount 35 mounting
bracket and lockwasher, the length of the bolt should not exceed 30 mm (approximately 1.125").
Group B should use the supplied knob-head bolts, OR an M8, grade 8.8 or better, 1.25 mm per thread, metric bolt,
that does not penetrate the cabinet past the cabinet surface more than 20 mm (approximately 3/4").
Insert C should use an M8 forged steel shoulder-type lifting eyebolt, which meets the requirements of DIN 580 or
ASTM A489, or whatever local, provincial or national suspension ordinances or regulations may additionally
require. The depth of penetration of the threaded shank on the eyebolts should not exceed 20 mm (approximately
3/4"), so that it does not engage the interior of the cabinet's sound absorbing lining. Thread pitch: 1.25 mm per
thread.
Notes on specific mounting methods using optional accessories
Mounting Method 1 - U-Bracket
Use the large handled knob-headed bolts to mate the U-Bracket to the cabinet, placing lockwashers between the
bracket and bolt. See diagram above. Determine the angle that the cabinet needs to be relative to the U-Bracket,
and position the cabinet to that angle, and screw-in a small handle knob-headed bolt through the threaded
angle-set hole in the bracket into one of the 24 angle location holes on the cabinet. Use the hole nearest the angle
desired.
For permanent installation, the large handled knob-headed bolts can be substituted for with hex head bolts by
using the specifications above (Group B). It is then recommended that thread-locker be used, and that a steel
metric M8 washer be used to prevent pull-through of the hex head. Using hex head bolts with thread-locker will
remove the possibility for someone to attempt to unscrew the knob-headed bolts by hand to vandalize or
otherwise alter the cabinets mounting.
If using the U-Bracket with the cabinet pointing straight out (bracket rear parallel to the rear of the cabinet), then
use of the NL-4 twist-lock connection is best made before locking the angle into place and using thread-locker.
Offset the cabinet till the NL-4 jack clears the bracket, and plug it up, then rotate the cabinet into the final position,
etc.
Mounting Method 2 - Peavey Versamount 35
Instructions for use are included with the Peavey Versamount 35, and for permanent installation, once the angles
have been finalized, use thread-locker on the four mounting bolts with lockwashers. The bolts for this method are
Group A.
Mounting Method 3 - Pole Mount Adapter
This adapter allows use of the cabinet with a speaker stand (also referred to as a tripod stand) for temporary
portable use. It is designed for use with a standard 1 3/8" (35 mm) diameter stand pole. This adapter is only
provided for use with the stand pole that is aligned basically straight up, no tilt should be present, or this could
cause an unsafe situation.