#7: Visual indications & acoustic
signals
Indications and signals:
The CO Sensor is equipped with a LED diode and a buzzer, signalling
menu position and status of the accessory.
Accessory status indications:
what
what you see
you hear
4 x BEEP
4 x RED BLINK
every 5s
every 5s
1 x YELLOw BLINK
1 x BEEP
every 30s
1 x BEEP
every 30s
1 x CYAN BLINK
2 x BEEP
every 30s
1 x BEEP
1 x wHITE BLINK
1 x GREEN BLINK
after button press
1 x GREEN BLINK
1 x BEEP
after powering
1 x RED BLINK
1 x BEEP
after powering
CYAN BLINKING
what it means
Detected pres-
ence of carbon
monoxide which
can kill you!
Low battery level
Sensor error
End of lifespan
Tamper alarm
Accessory
powered
Paired with
HomeKit
Not paired with
HomeKit
Firmware update
what to do
1. Open the windows
2. Move to fresh air!
3. Contact emergency
services
Replace the battery
Reset the accessory,
replace if no effect
Reset the accessory,
replace if no effect
Check the housing
wait for completion
VISuAL INDICATIONS & ACOuSTIC SIGNALS
9
i
NOTE
Replace the accesso-
ry before date on the
front or if sensor error
is detected.